Skip to guide

Tool guide

ADMET-AI online

Predict ADMET properties online with ADMET-AI. Prepare compound panels, interpret endpoint scores and reference percentiles, and prioritize follow-up assays.

Inputs
1–250 small molecules
Workflow
Broad ADMET property panel
Results
Endpoint predictions in a downloadable CSV
On this page

Overview

ADMET-AI predicts absorption, distribution, metabolism, excretion, and toxicity properties from molecular structure. Submit a compound panel to review potential liabilities and tradeoffs before selecting molecules for synthesis, DMPK assays, or further modeling.

Use it for a broad initial profile rather than a single all-purpose drug score. A compound can look favorable on one endpoint and unfavorable on another, and the desired balance depends on the research objective.

Questions you can investigate

  • Which analogs combine useful solubility and permeability predictions?
  • Do predicted CYP or transporter liabilities change across a chemical series?
  • Which potential toxicity signals deserve a targeted assay?
  • Which compounds provide informative contrasts for an experimental panel?

For a focused selection of ADMET endpoints, consider Admetica. The two services use different models and endpoint definitions; their numbers are not automatically interchangeable.

Method & workflow

Endpoint-specific molecular predictions

ADMET-AI uses Chemprop-based molecular models. The published study describes evaluation across 41 Therapeutics Data Commons datasets. See the official documentation for model and endpoint background.

Some endpoints are classification tasks; others are regression estimates on assay-specific scales. Training on multiple datasets does not mean that every chemistry or biological setting is equally represented. Keep the returned column definitions and model version attached to each analysis.

This workflow predicts properties from molecular representations. It does not simulate a complete organism, calculate a dose, or measure a compound’s pharmacokinetics experimentally.

Inputs & settings

Prepare a traceable compound panel

Input Molecules accepts 1–250 molecules, each with 5–1,000 atoms, as SMILES, SDF, or CCD entries. Inputs are converted to SMILES; a bound 3D pose or receptor structure is not required.

Check connectivity, bond orders, stereochemistry, formal charges, and the intended protonation or tautomeric state. Handle salts, counterions, and mixtures consistently with your research question. A valid SMILES string does not guarantee that a molecule is represented by the model’s training chemistry.

Keep a compound-ID-to-structure mapping outside the result table. Invalid molecules may be skipped, so reconcile the returned molecule identities and row count with the submitted panel; do not match results by row number alone. See preparing inputs.

Start with controls and matched analogs

The form exposes the molecule input, without endpoint-selection or assay-condition settings. Begin with a small panel containing a relevant reference compound and matched analogs. Inspect the endpoint columns before expanding the screen; split larger libraries into bounded batches using bulk submission guidance.

Results & interpretation

Interpret results.csv by endpoint

The table and results.csv identify each returned compound by its molecule SMILES and provide endpoint predictions. Preserve full column names, including dataset identifiers and any percentile suffixes.

Output type How to read it
Classification output Model support for the endpoint’s defined positive class. Verify that class: “positive” is not universally favorable.
Continuous prediction An endpoint-specific estimate. Check units, assay context, and whether the target was log-transformed before applying a threshold.
Physicochemical descriptor A molecular property or rule-based descriptor, not experimental evidence of exposure or activity.
Reference percentile, where returned Relative position within the model’s reference distribution. It is not confidence, a probability of clinical success, or a universal desirability score.

Do not add unrelated columns into one score without a defined decision rule. A 0–1 classification value is not a concentration, IC50, or potency measurement. A logged solubility or clearance target is not the corresponding linear quantity.

A higher value is not always better: CYP inhibition or toxicity-class support has a different interpretation from solubility. Even for solubility, permeability, protein binding, or clearance, the desired balance depends on the project rather than a universal pass/fail rule.

Worked plan: choose an informative analog assay panel

This illustrative workflow has not been executed for this guide.

  1. Prepare one reference compound and a small matched analog series, preserving identifiers and exact molecular structures.
  2. Submit the panel through Input Molecules after reviewing credit guidance.
  3. Download results.csv, match every returned SMILES to the input mapping, and account for missing compounds.
  4. Choose a few endpoints relevant to the project. Verify class labels and regression scales in the ADMET-AI documentation before defining provisional selection criteria.
  5. Select compounds spanning useful predicted tradeoffs, rather than retaining only one top-ranked molecule. Check related chemistry and any available experimental reference values.
  6. Measure the selected endpoints under consistent assay conditions, keeping measured values separate from predictions.

Compare services and preserve evidence

If using Admetica as a complementary view, compare matched molecules and endpoints only after checking target definitions and transformations. Agreement is useful for prioritization, while disagreement can motivate an assay; shared data or modeling approaches mean the results are not necessarily independent validation.

Save submitted structures, preparation conventions, compound mappings, service version, job date, selection criteria, and the original CSV in a project. The current table does not establish a molecule-specific error interval or applicability-domain guarantee.

Explore ADMET prediction workflows, small-molecule discovery, and GNINA docking for complementary research steps. A good docking result does not resolve an ADMET liability.

Research applications

  • Broad first pass: Review multiple endpoint predictions for each compound.
  • Analog comparisons: Explore predicted tradeoffs within a matched chemical series.
  • Assay planning: Select informative compounds for targeted measurements.
  • Portable output: Preserve endpoint-level CSV results and compound identities.

Get started

Run ADMET-AI on Neurosnap

  1. Prepare your inputs

    Check the tool's accepted formats and molecular requirements. Keep a copy of the exact inputs.

  2. Configure the calculation

    Open the tool, supply your inputs, and review the available settings and credit estimate.

  3. Submit and follow the job

    Submit once and save the job ID. Track execution in your workspace.

  4. Review the results

    Inspect the returned outputs in context and preserve the settings needed to reproduce your analysis.

Frequently asked questions

Do I need a receptor or a 3D binding pose?

No. This service predicts from molecular structures converted to SMILES. It does not use a receptor or docking pose as an input.

Is a high reference percentile always favorable?

No. A percentile describes position in a reference distribution. Its desirability depends on the endpoint, and it is not model confidence.

Why are some submitted compounds missing?

Invalid molecules may be skipped. Reconcile returned SMILES with your input mapping and check molecular validity before resubmitting missing compounds.

Can I choose only selected endpoints?

This form returns a broad panel without endpoint-selection controls. Admetica offers selected-property runs.

Can I average ADMET-AI and Admetica values?

Not without checking units, transforms, positive-class definitions, and assay targets. Similar column labels do not establish equivalent outputs.

References & citation

Cite the original method when using it in publications or research outputs.

  • Kyle Swanson, Parker Walther, Jeremy Leitz, Souhrid Mukherjee, Joseph C Wu, Rabindra V Shivnaraine, James Zou, ADMET-AI: a machine learning ADMET platform for evaluation of large-scale chemical libraries, Bioinformatics, Volume 40, Issue 7, July 2024, btae416, https://doi.org/10.1093/bioinformatics/btae416

Original publication

Your next calculation

Put the method to work.

Run scientific tools in your browser and keep inputs, jobs, and results together.